How to Change Adhesive in Dual-Component Dispensing Machines
2026-01-15 15:45:39Switching adhesives in dual-component dispensing machines requires thorough cleaning to prevent chemical reactions or quality issues caused by residual mixing. Follow these steps for safe and efficient operation.
I. Preparation
Confirm Adhesive Type: Consult suppliers to identify suitable cleaning agents (e.g., industrial alcohol, acetone-based solvents).
Close Valves: Seal the bottom valves of the A/B material tanks to isolate them.
II. Cleaning Process
Empty Residual Adhesive: Operate the machine to dispense and purge all remaining adhesive from the dispensing valve, high-pressure PTFE tubing, and A/B pumps.
Power Off: Disconnect the machine’s main power supply.
Clean Material Tanks:
Remove the bottom tubing and drain residual adhesive.
After closing valves, pour cleaning agent into the tanks and scrub internal surfaces thoroughly.
Clean A/B Pumps:
Detach the pumps (requires professional assistance) and remove internal adhesive residue.
III. Adhesive Replacement
Reinstall Components: Return cleaned A/B pumps to their positions and reconnect tubing.
Replace Tubing: Install new high-pressure PTFE tubing if worn or contaminated.
Load New Adhesive: Pour fresh adhesive into tanks, then run the machine in "Jog Mode" for 3–5 minutes to verify smooth dispensing.
Adjust Ratio: Calibrate the A/B mixing ratio as per specifications.
IV. Key Considerations
Safety: Wear waterproof gloves and ensure adequate ventilation during cleaning.
Maintenance: For machines without auto-cleaning functions, schedule manual cleaning cycles to prevent buildup.